Showing 65–80 of 118 results

MENHIR-1550 SERIES

 Michael Iluz

Key Features:

  • Ultra-low noise
  • Transform-limited pulses
  • Compact industrial design
  • Harsh environment resistant
  • User friendly
  • Turnkey system
  • 24/7 operation
  • All-in-one system

MicAO 3DSR – High Resolution 3D for SMLM

 Johanna Taieb

BEST FOR
– Photoactivation localization microscopy (PALM)
– Stochastic optical reconstruction microscopy (STORM)
– Single particle tracking (SPT)

KEY FEATURES
– Corrects aberrations and restores diffraction-limited PSF
– Delivers best 2D and 3D localization precision for PALM/STORM imaging
– Doubles the number of detected photons and improves localization precision
– High temporal stability of the correction

MicAO: Adaptive Optics add-on module for SMLM

 Miki Iluz

Features:

  • Restores Point Spread Function (PSF) symmetry
  • Doubles the number of detected photons
  • Improves near diffraction-limited resolution
  • Allows you to create a perfect PSF ecoding astigmatism or tetrapod to go 3D
  • Gives you a better 2D and 3D localization precision
  • Is compatible with long-term imaging

Mirao 52e – Optimized for closed-loop operations Copy

 Johanna Taieb

BEST FOR
– Bio-imaging
– Ophthalmology
– Microscopy
– Beam shaping

KEY SPECS
– ±50 µm stroke (tilt p/v)
– 15 mm pupil with 52 actuators
– Exceptional surface quality (less than 10 nm rms active flat)
– Virtually no hysteresis (less than 2%)
– Near perfect linearity (over 95%)
– Compatible with open-loop control
– USB2 connectivity

Mirao 52es – For long-term wavefront stability

 Johanna Taieb

KEY SPECS
– ±50 µm stroke (tilt p/v)
– 15 mm pupil with 52 actuators
– Exceptional surface quality (<10 nm rms active flat)
– Virtually no hysteresis (<2%) – Near perfect linearity (>95%)
– Compatible with open-loop control
– USB2 connectivity
– Ultra-high temporal stability

Mode Fiels Adaptator (MFA)

 Johanna Taieb

Key Features:

  • High Signal Transfer Efficiency
  • Low Degradation of Beam Quality
  • High Power Operation (Forward version)
  • Wide Wavelength Range Applicable
  • Customized Configurations Available

mu-DM: Deformable mirror for microscopy & ophthalmology

 Miki Iluz

Features of µDM deformable mirror for microscopy

  • Fast closed-loop convergence and accurate sensorless correction with perfect linearity and absence of hysteresis
  • Preserved photon budget with achromatic, highly reflective and continuous membrane
  • Long-term stability with temporal drift automatic compensation
  • Large dynamic range with 50% of actuators stroke still available while generating 40 microns PtV of focus
  • Fine timing control with trigger-in and trigger-out features
  • Easy integration with electronics embedded in a single-piece design and connection via a USB3 cable
  • Correction up to 10th Zernike order thanks to optimized actuator layout