Showing 17–32 of 51 results
Miki Iluz
Choose your elements depending on your needs : AO loop can be integrated with different phase modulators, such as deformable mirrors or spatial light modulators (SLM)
Doubles the number of detected photons
Operate in both closed and open loop mode
Save time implementing your AO set-up
Miki Iluz
Key Features
Absolute accuracy 600MHz
Measurement precision 50MHz
Up to 250 measurements/s
Operation over 400-1100nm without recalibration
Rapid on-device measurement, no host computer required!
Integrated PID controller for wavelength stabilisation
Interactive display for control and diagnostics
Ethernet and USB interfaces
Compact form-factor, 146 x 120 x 81 mm
Michael ILUZ
Main features:
Highest beam pointing stability (< 0,1 mrad)
All-in-one design with integrated controller
Two lenses simultaneous movement assuring no misfocus
Absolute encoder (both lenses)
Adjustment time <1s (all magnifications)
Fused silica optical elements
No homing after switching on/off
Diffraction limited performance for all magnifications
Application examples:
Precise laser micromachining
Life sciences
Research
Michael Iluz
Key Features:
High energy
Compact
Highly configurable pulses
Air-cooled
Michael Iluz
Key Features:
Narrow Linewidth: ≤ 0.5 MHz
High Power Stability: ≤ 2.0 %
High Spectral Stability: ± 1.0 pm
Designed for Integration
Michael Iluz
Key Features:
Narrow Linewidth: ≤ 0.5 MHz
High Power Stability: ≤ 2.0 %
High Spectral Stability: ± 1.0 pm
Excellent Beam Quality
Michael Iluz
Key Features:
High-bandwidth PID or PI²D control
All-analogue signal processing with propagation delay 40ns
Parallel FAST and SLOW control loops
Feedback to both current and piezo
Flexible control of loop parameters
High-bandwidth external modulation
Internal ramp generator
Two low-noise photodiode power supplies
TTL control
Michael ILUZ
Main features:
Divergence adjustment
Galilean optical design
UVFS optical elements
Grease free mechanical design
Wide wavelenght adoption – 200 nm to 2 μm
Application examples:
Laser materials processing
Medical
Research
Johanna Taieb
BEST FOR
– Adaptive Optics applications for microscopy or UHIL
– OEM applicaitons in optical metrology and beam diagnostics
– AO for high-power laser optimization
Michael ILUZ
Main features:
High power optical design (up to 200 W @ 1030 nm, 500 fs, 1 Mhz)
No internal reflections on optical elements
High beam pointing stability <0,2 mrad
All-in-one design with integrated controller
Two lens simultaneous movement assuring no misfocus
Absolute encoder (both lenses)
Fused silica optical elements
Diffraction limited performance for all magnifications
Application examples:
Precise laser micromachining
High power laser beam management
Research
Michael Iluz
Key Features:
Ultra-low noise
Transform-limited pulses
Compact industrial design
Harsh environment resistant
User friendly
Turnkey system
24/7 operation
All-in-one system
VIDEO
Johanna Taieb
BEST FOR
– Photoactivation localization microscopy (PALM)
– Stochastic optical reconstruction microscopy (STORM)
– Single particle tracking (SPT)
KEY FEATURES
– Corrects aberrations and restores diffraction-limited PSF
– Delivers best 2D and 3D localization precision for PALM/STORM imaging
– Doubles the number of detected photons and improves localization precision
– High temporal stability of the correction
Miki Iluz
Features:
Restores Point Spread Function (PSF) symmetry
Doubles the number of detected photons
Improves near diffraction-limited resolution
Allows you to create a perfect PSF ecoding astigmatism or tetrapod to go 3D
Gives you a better 2D and 3D localization precision
Is compatible with long-term imaging
Bernard Azout
Key Features:
Air-cooled system
Ultra compact
Ideal for biophotonics and imaging applications
Optional green output
Johanna Taieb
BEST FOR
– Bio-imaging
– Ophthalmology
– Microscopy
– Beam shaping
KEY SPECS
– ±50 µm stroke (tilt p/v)
– 15 mm pupil with 52 actuators
– Exceptional surface quality (less than 10 nm rms active flat)
– Virtually no hysteresis (less than 2%)
– Near perfect linearity (over 95%)
– Compatible with open-loop control
– USB2 connectivity
Johanna Taieb
KEY SPECS
– ±50 µm stroke (tilt p/v)
– 15 mm pupil with 52 actuators
– Exceptional surface quality (<10 nm rms active flat)
– Virtually no hysteresis (<2%) – Near perfect linearity (>95%)
– Compatible with open-loop control
– USB2 connectivity
– Ultra-high temporal stability